“Tubing blocked” and blocked-airway messages on a CPAP machine
The opposite of a leak: air cannot get through. The makers name a folded or squashed tube, something over the air inlet, or a blocked filter.
Therapy settings: This page explains what a CPAP machine’s screen or light is telling you, in the maker’s words. It is not medical advice: ask your equipment provider or clinician about your therapy settings, and do not change your pressure or any prescribed setting because of anything here.
ResMed
ResMed AirSense 10 Words on the screen
Tubing blocked, check your tubing
The air tubing may be blocked.
What ResMed says to do
- Check the air tubing and remove any blockage.
- Press the dial to clear the message, then press Start/Stop to restart.
Source: AirSense 10 user guide (AirSense 10 AutoSet, AutoSet for Her, Elite and CPAP, with HumidAir) (ResMed, 378947/1, 2021-02), checked 2026-09-29.
Everything else ResMed’s machines show: ResMed CPAP icons and messages.
Philips Respironics
Philips Respironics DreamStation 2 Words on the screen
Blocked inlet
Blocked airway: something is blocking the air inlet on the machine.
What Philips Respironics says to do
- Check the air inlet is not obstructed.
- Check the air filter(s) are installed properly; replace them if needed.
Source: DreamStation 2 Auto CPAP / CPAP user manual (Philips Respironics, 1143534 R02, 06/11/2021), checked 2026-09-29.
Philips Respironics DreamStation 2 Words on the screen
Low leak
Blocked airway: a blockage at the tube or the mask.
What Philips Respironics says to do
- Check the tube is not crushed or folded so that air flow is restricted.
- Check the mask is attached properly and nothing is obstructing it.
Source: DreamStation 2 Auto CPAP / CPAP user manual (Philips Respironics, 1143534 R02, 06/11/2021), checked 2026-09-29.
Philips Respironics DreamStation (first generation) Words on the screen
Inlet blocked. Check filter.
Blocked airway: something is blocking the air inlet on the machine.
What Philips Respironics says to do
- Check the machine’s air inlet is not obstructed.
- Check the air filter or filters are installed properly; replace them if needed.
Source: DreamStation CPAP, CPAP Pro, Auto CPAP user manual (Philips Respironics, 1152070 R00, 08/27/2021), checked 2026-09-29.
Philips Respironics DreamStation (first generation) Words on the screen
Low Leak: Check Mask and Tube
Blocked airway: a blockage at the tube or the mask.
What Philips Respironics says to do
- Check the tube is not crushed or folded so that airflow is restricted.
- Check the mask is attached properly and nothing is blocking it.
Source: DreamStation CPAP, CPAP Pro, Auto CPAP user manual (Philips Respironics, 1152070 R00, 08/27/2021), checked 2026-09-29.
Philips Respironics DreamStation Go Words on the screen
Inlet blocked. Check filter.
Blocked airway: something is blocking the air inlet on the machine.
What Philips Respironics says to do
- Check the machine’s air inlet is not obstructed.
- Check the air filter or filters are installed properly; replace them if needed.
Source: DreamStation Go Auto CPAP / CPAP user manual (Philips Respironics, 1152853 R01, 06/14/2022), checked 2026-09-29.
Philips Respironics DreamStation Go Words on the screen
Low leak: Check mask and tube
Blocked airway: a blockage at the tube or the mask.
What Philips Respironics says to do
- Check the tube is not crushed or folded so that airflow is restricted.
- Check the mask is attached properly and nothing is blocking it.
Source: DreamStation Go Auto CPAP / CPAP user manual (Philips Respironics, 1152853 R01, 06/14/2022), checked 2026-09-29.
Everything else Philips Respironics’s machines show: Philips Respironics CPAP icons and messages.
React Health
React Health Luna G3 Something the machine does
Air from the machine is unusually hot
The air inlet may be partly blocked, so too little air is getting into the machine.
What React Health says to do
- Replace the air filter (or the optional ultra-fine filter) and clean the air inlet.
- Put the machine where air flows freely, at least 20 cm from walls, curtains and other objects.
Source: Luna G3 APAP / Luna G3 CPAP User Manual (React Health, V1.7, issue date February 29, 2024), checked 2026-09-29.
Everything else React Health’s machines show: React Health CPAP icons and messages.
Other things a CPAP machine shows
Sources
Each maker’s own user guide only, read on the date shown. Nothing here comes from third-party CPAP forums or “error code” sites.
- ResMed: AirSense 10 user guide (AirSense 10 AutoSet, AutoSet for Her, Elite and CPAP, with HumidAir) — 378947/1, 2021-02. document.resmed.com Checked 2026-09-29.
- Philips Respironics: DreamStation 2 Auto CPAP / CPAP user manual — 1143534 R02, 06/11/2021. www.documents.philips.com Checked 2026-09-29.
- React Health: Luna G3 APAP / Luna G3 CPAP User Manual — V1.7, issue date February 29, 2024. www.reacthealth.com Checked 2026-09-29.
- Philips Respironics: DreamStation CPAP, CPAP Pro, Auto CPAP user manual — 1152070 R00, 08/27/2021. www.philips.com Checked 2026-09-29.
- Philips Respironics: DreamStation Go Auto CPAP / CPAP user manual — 1152853 R01, 06/14/2022. www.philips.com Checked 2026-09-29.