What does this symbol on medical packaging mean?

Find it by its shape. 1. Pick what you see on the box, pouch or label. 2. Match the drawing. Each of the 85 symbols here has its own page with the standard’s wording, quoted from at least two publishers’ public documents.

Whether a device is right for you is a question for your pharmacist, nurse or doctor.

Tap a shape — the symbols that use it appear here.

A factory — 3 symbols

↑ Pick a different shape

An hourglass — 1 symbol

↑ Pick a different shape

Letters — 13 symbols

↑ Pick a different shape

The word STERILE — 9 symbols

↑ Pick a different shape

A crossed-out circle — 11 symbols

↑ Pick a different shape

Limit lines — 3 symbols

↑ Pick a different shape

Umbrella, sun or glass — 4 symbols

↑ Pick a different shape

A triangle — 10 symbols

↑ Pick a different shape

Warnings — 3 symbols

↑ Pick a different shape

Arrows — 7 symbols

↑ Pick a different shape

MR — 3 symbols

↑ Pick a different shape

A book — 2 symbols

↑ Pick a different shape

A rounded triangle — 7 symbols

↑ Pick a different shape

Ovals — 4 symbols

↑ Pick a different shape

Tubes, lines and valves — 5 symbols

↑ Pick a different shape

A person or a heart — 12 symbols

↑ Pick a different shape

A card, screen or calendar — 3 symbols

↑ Pick a different shape

An alarm triangle or a bell — 6 symbols

↑ Pick a different shape

Blue, red or yellow safety signs — 5 symbols

↑ Pick a different shape

Marks on the device casing — 9 symbols

↑ Pick a different shape

Reading a medical label: the four marks people ask about

Where these come from. ISO 15223-1:2021 “Medical devices — Symbols to be used with information to be supplied by the manufacturer — Part 1: General requirements” is a paid standard, so this page does not reproduce it. Each meaning is quoted as the cited public documents — manufacturers’ symbol glossaries, MedTech Europe’s guidance and US FDA and eCFR texts — reproduce it. The three MR marks come from ASTM F2503, which FDA’s MR labelling guidance follows, and “Rx only” from the US regulation 21 CFR 801.109. The applied-part marks (type B, BF, CF and their defibrillation-proof versions) are not ISO 15223-1 symbols: they are IEC 60417 graphical symbols that IEC 60601-1 requires on medical electrical equipment, so you find them on the device or its cable rather than on the box. The same holds for the marks printed on monitors, infusion pumps, oxygen concentrators and other medical electrical equipment: the alarm symbols (alarm, alarm off, alarm paused, audio off, audio paused, alarm reset) are IEC 60417 symbols used by IEC 60601-1-8, the alarm-systems standard, and IEC 60601-1 lists the rest in its Table D.1 (symbols such as equipotentiality) and Table D.2 (safety signs such as the blue follow instructions for use disc).

What this page cannot do

Left out, and why

Drawings semiatic already explains keep their one page: the Protective earth (IEC 60417-5019, IEC 60601-1, Table D.1, symbol 6), the Class II equipment (IEC 60417-5172, IEC 60601-1, Table D.1, symbol 9), the Stand-by (IEC 60417-5009, IEC 60601-1, Table D.1, symbol 29), the Dangerous voltage (lightning arrow) and the yellow “warning, electricity” sign (IEC 60417-5036, IEC 60601-1, Table D.1, symbol 24 and Table D.2, safety sign 3 (ISO 7010-W012)), the Alternating current (IEC 60417-5032, IEC 60601-1, Table D.1, symbol 1), the “ON”/“OFF” push-push (IEC 60417-5010, IEC 60601-1, Table D.1, symbol 14) — each has an “On medical equipment” section there.

Drawn twice on semiatic, with different meanings: Consult instructions for use (ISO 15223-1:2021, 5.4.3) and Book (read the operator’s manual); Temperature limit (ISO 15223-1:2021, 5.3.7 (with 5.3.5 and 5.3.6)) and Temperature limits (minimum and maximum °C). Each medical page says how the two differ.

Sources

Every document below is public and was fetched and checked on the date shown: manufacturers’ symbol glossaries, MedTech Europe’s guidance, and US FDA and eCFR texts. Each symbol page lists what its sources show.

Made with AI tools. · Privacy