Bradford White gas water heater: what the status light means

If you smell gas

Stop: do not relight or troubleshoot anything. Bradford White’s own words (first page of both Installation and Operation Manuals, 238-51007-00R and the Ultra Low NOx 238-53393-00K):

  • DO NOT try to light any appliance.
  • DO NOT touch any electrical switch.
  • DO NOT use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

Calling from a neighbor’s phone means leaving the building first.

Bradford White’s gas water heaters with the ICON System electronic gas control have one status LED on the control. Its Installation and Operation Manual gives three separate LED tables, because ICON controls have been made by Resideo (two versions, V1 and V2) and by SIT, and the same pattern does not always mean the same thing on each. Bradford White’s own FAQ calls the flashing light a feature designed to help the professional plumber, and says to contact a plumbing professional if the heater has operating issues; the owner-level meaning is what these pages give.

The LED is on the ICON gas control on the front of the tank, with the set point knob (OFF, PILOT and temperature settings). The manual’s tables are headed by the control’s maker — Resideo V1, Resideo V2 or SIT; only the Resideo V2 table names LED colours (green, yellow, red). Heaters with the mechanical White Rodgers gas control have no status LED. If you cannot tell which control you have, each page here shows what every table says for that pattern.

14 patterns, in blink order. Each has our drawing, Bradford White’s meaning, the steps it gives the owner and its source. Find the brand and model on the rating plate first: the same count means different things on different makers’ heaters.

LED off, not flashing

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: Millivolt power is not present: the pilot is out, so the gas valve is not powered.
ICON control by Resideo, V2: Millivolt power is not present: the gas valve is not powered.
ICON control by SIT: The control is off: the main burner and the pilot burner are both off.

Bradford White gas control: the status light is off
Our drawing of a gas control valve: the status light is off.

Bradford White’s manual has 3 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: the status light is off. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “None (LED not on or flashing)”.

Millivolt power is not present: the pilot is out, so the gas valve is not powered.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2

The manual’s wording: “None (LED not on or flashing)”.

Millivolt power is not present: the gas valve is not powered.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by SIT

The manual’s wording: “None (LED not on or flashing)”.

The control is off: the main burner and the pilot burner are both off.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

  1. Bradford White says to light the pilot, following the lighting instructions for the ICON control.
  2. Bradford White says to light the pilot.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: Status light off (The combination gas control is turned off, or the pilot is not lit, so there is no millivolt power from the thermopile to light the status light.); A.O. Smith: Status light off (0 flashes) (The pilot light is not lit, or there is not enough power (millivolts) from the thermopile to keep it lit.).

Source:

On its own page: LED off, not flashing

1 flash, then a pause of 3 to 4 seconds

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: No fault.
ICON control by Resideo, V2: Not an error: the pilot is lit and the main burner is off.
ICON control by SIT: Not an error: the pilot is lit and the main burner is off. Not a fault.

Bradford White gas control: one flash, then a pause, repeating
Our drawing of a gas control valve: one flash, then a pause, repeating.

Bradford White’s manual has 3 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: one flash, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “One flash and three second pause”.

No fault. With the knob at PILOT, the pilot flame is detected and the valve is powered, waiting for the knob to be turned to a water temperature. With the knob already at your setting, the thermostat is satisfied (the water is up to temperature).

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2

The manual’s wording: “One flash every four seconds (LED green)”.

Not an error: the pilot is lit and the main burner is off.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by SIT

The manual’s wording: “One flash every four seconds”.

Not an error: the pilot is lit and the main burner is off. The valve is powered and waiting for the knob to be turned to a temperature, or, with the knob at your setting, the thermostat is satisfied.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

  1. Bradford White says the valve is waiting for the set point knob to be turned to a water temperature setting.
  2. Bradford White says you can now turn the knob to the temperature you want.

This pattern is normal operation. If the light shows a fault code instead, or you have no hot water with the light normal and the knob set correctly, call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 1 blue blink every 3 seconds (Normal operation: the pilot is lit.); A.O. Smith: 1 flash every 3 seconds (Normal operation: the pilot is lit and the gas control valve has not detected any problem.).

Source:

On its own page: 1 flash, then a pause of 3 to 4 seconds

1 flash every second

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V2: Not an error: the main valve is open and the main burner is lit, heating the water.
ICON control by SIT: Not an error: the main valve is open and the main burner is lit. Not a fault.

Bradford White gas control: one flash every second, over and over
Our drawing of a gas control valve: one flash every second, over and over.

Bradford White’s manual has 2 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: one flash every second, over and over. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V2

The manual’s wording: “One flash every second (LED green)”.

Not an error: the main valve is open and the main burner is lit, heating the water. The control shuts the burner off by itself when the water reaches the set temperature.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by SIT

The manual’s wording: “One flash every second”.

Not an error: the main valve is open and the main burner is lit. The thermostat is calling for heat and the heater is in a heating cycle.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: it is normal operation.

This pattern is normal operation. If the light shows a fault code instead, or you have no hot water with the light normal and the knob set correctly, call a qualified service agency: Bradford White’s service line, below.

Source:

On its own page: 1 flash every second

2 quick flashes (a strobe), then a pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

No fault: the thermostat is calling for heat and the water heater is operating normally. Not a fault.

Bradford White gas control: two quick flashes, then a pause, repeating
Our drawing of a gas control valve: two quick flashes, then a pause, repeating.

What you see: two quick flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means

The manual’s wording: “LED strobe (two quick flashes) and three second pause” — ICON control by Resideo, V1.

No fault: the thermostat is calling for heat and the water heater is operating normally.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: it is normal operation.

This pattern is normal operation. If the light shows a fault code instead, or you have no hot water with the light normal and the knob set correctly, call a qualified service agency: Bradford White’s service line, below.

Source:

LED on steady

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: The set point knob has recently been turned to OFF.
ICON control by Resideo, V2: Not an error: the control is in OFF mode.
ICON control by SIT: Not an error: the control is in shutdown mode because the set point knob was recently turned to OFF. Not a fault.

Bradford White gas control: the status light is on steady, not flashing
Our drawing of a gas control valve: the status light is on steady, not flashing.

Bradford White’s manual has 3 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: the status light is on steady, not flashing. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “LED on continuously”.

The set point knob has recently been turned to OFF.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2

The manual’s wording: “Solid ON (LED red)”.

Not an error: the control is in OFF mode.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by SIT

The manual’s wording: “Solid ON”.

Not an error: the control is in shutdown mode because the set point knob was recently turned to OFF.

Not a fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

  1. Bradford White says to wait until the LED goes out before attempting to relight.
  2. Bradford White says to wait until the LED turns off if you want to restart the system.

This pattern is normal operation. If the light shows a fault code instead, or you have no hot water with the light normal and the knob set correctly, call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: Status light on steady (The pilot was recently put out and the thermopile is cooling down, or the temperature knob was recently turned to OFF.); A.O. Smith: Status light on solid (The pilot was lit but is now off, and the thermopile is still cooling down.).

Source:

On its own page: LED on steady

2 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: Weak pilot flame detected.
ICON control by Resideo, V2: Low thermopile voltage, so the main valve is not turned on.
ICON control by SIT: Low thermopile voltage; the main burner is not lit.

Bradford White gas control: 2 flashes, then a pause, repeating
Our drawing of a gas control valve: 2 flashes, then a pause, repeating.

Bradford White’s manual has 3 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: 2 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “Two flashes and three second pause”.

Weak pilot flame detected. The system resets itself when the pilot flame is sufficient.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2

The manual’s wording: “Two flashes and three second pause (LED yellow)”.

Low thermopile voltage, so the main valve is not turned on.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by SIT

The manual’s wording: “Two flashes and three second pause”.

Low thermopile voltage; the main burner is not lit.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • ICON control by Resideo, V2: check the thermopile and its connections; check the pilot flame.
  • ICON control by SIT: probable cause: loose thermopile connections or a weak pilot flame.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 2 red blinks every 3 seconds (Low thermopile voltage, although the pilot is lit.); A.O. Smith: 2 flashes, then a pause (Insufficient power (millivolts) reaching the gas control valve/thermostat from the thermopile.).

Source:

On its own page: 2 flashes, then a 3-second pause

3 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

Insufficient water heating. The system resets itself.

Bradford White gas control: 3 flashes, then a pause, repeating
Our drawing of a gas control valve: 3 flashes, then a pause, repeating.

What you see: 3 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means

The manual’s wording: “Three flashes and three second pause” — ICON control by Resideo, V1.

Insufficient water heating. The system resets itself.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • probable cause: the temperature sensor is out of calibration, or a possible short.

When to call a qualified service agency: Bradford White’s service line, below.

Source:

4 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: Excessive tank temperature.
ICON control by Resideo, V2: The temperature cut-out limit was reached, causing a shutdown.
ICON control by SIT: The temperature cut-out limit was reached, causing a shutdown; excessive temperatures may have been reached.

Bradford White gas control: 4 flashes, then a pause, repeating
Our drawing of a gas control valve: 4 flashes, then a pause, repeating.

Bradford White’s manual has 3 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: 4 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “Four flashes and three second pause”.

Excessive tank temperature. The table says the system must be reset.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2

The manual’s wording: “Four flashes and three second pause (LED red)”.

The temperature cut-out limit was reached, causing a shutdown.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by SIT

The manual’s wording: “Four flashes and three second pause”.

The temperature cut-out limit was reached, causing a shutdown; excessive temperatures may have been reached.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • ICON control by Resideo, V1: probable cause: the temperature sensor is out of calibration, or a faulty gas valve.
  • ICON control by Resideo, V2: check the valves and the water temperature sensor; reduce the water temperature setpoint; verify the control’s operation and replace it if it heats past the setpoint.
  • ICON control by SIT: shut off the control and reduce the water temperature; thoroughly verify the control’s operation and replace it if it heats past the setpoint.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 4 red blinks every 3 seconds (The high water temperature limit has tripped: the water got hotter than the control’s safety limit, and the heater has shut down.); A.O. Smith: 4 flashes, then a pause (High water temperature has activated the overheat sensor (State’s handbook calls it “temperature exceeded (ECO activated)”).).

Source:

5 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: Temperature sensor fault.
ICON control by Resideo, V2: An electronics, sensor or gas valve fault has been detected.
ICON control by Resideo, V2, on Ultra Low NOx models: Water temperature sensor failure.
ICON control by SIT: An electronics, sensor or gas valve fault has been detected.

Bradford White gas control: 5 flashes, then a pause, repeating
Our drawing of a gas control valve: 5 flashes, then a pause, repeating.

Bradford White’s manual has 4 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: 5 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “Five flashes and three second pause”.

Temperature sensor fault.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2

The manual’s wording: “Five flashes and three second pause (LED red)”.

An electronics, sensor or gas valve fault has been detected.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2, on Ultra Low NOx models

The manual’s wording: “Five flashes and three second pause (LED red)”.

Water temperature sensor failure.

Source: Ultra Low NOx Gas Water Heater Installation and Operation Manual (238-53393-00K, REV 08/26), “Troubleshooting — Resideo V1” and “Troubleshooting — Resideo V2”.

ICON control by SIT

The manual’s wording: “Five flashes and three second pause”.

An electronics, sensor or gas valve fault has been detected. The control may be wet or damaged.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • ICON control by Resideo, V1: check the temperature wire for damage and the sensor’s resistance, and replace the temperature sensor; if that does not correct it, verify the control is not wet or physically damaged, turn the knob to OFF, then to PILOT, and light the pilot; replace the gas valve if the five-flash error persists.
  • ICON control by Resideo, V2: check the water temperature sensor and its connection for open circuits, shorts or differences in resistance between the two sensor elements.
  • ICON control by Resideo, V2, on Ultra Low NOx models: check the valves and the water temperature sensor; reduce the water temperature setpoint; thoroughly check the main valve and water temperature control before walking away.
  • ICON control by SIT: verify all connections are tight; if the problem persists, replace the control.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 5 red blinks every 3 seconds (Water temperature sensor failure.); A.O. Smith: 5 flashes, then a pause (Sensor failure: the temperature sensor in the gas control valve has failed.).

Source:

On its own page: 5 flashes, then a 3-second pause

6 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

ICON control by Resideo, V1: A water leak has been detected by an accessory module (some models only): an excessive amount of water in the drain pan or water dam.
ICON control by Resideo, V2, on Ultra Low NOx models: Door temperature sensor failure.

Bradford White gas control: 6 flashes, then a pause, repeating
Our drawing of a gas control valve: 6 flashes, then a pause, repeating.

Bradford White’s manual has 2 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: 6 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “Six flashes and three second pause”.

A water leak has been detected by an accessory module (some models only): an excessive amount of water in the drain pan or water dam.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2, on Ultra Low NOx models

The manual’s wording: “Six flashes and three second pause (LED red)”.

Door temperature sensor failure.

Source: Ultra Low NOx Gas Water Heater Installation and Operation Manual (238-53393-00K, REV 08/26), “Troubleshooting — Resideo V1” and “Troubleshooting — Resideo V2”.

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • ICON control by Resideo, V2, on Ultra Low NOx models: check the door temperature sensor and its connection for open circuits or shorts.

When to call a qualified service agency: Bradford White’s service line, below.

Source:

On its own page: 6 flashes, then a 3-second pause

7 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

A gas valve electronic fault has been detected.

Bradford White gas control: 7 flashes, then a pause, repeating
Our drawing of a gas control valve: 7 flashes, then a pause, repeating.

What you see: 7 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means

The manual’s wording: “Seven flashes and three second pause” — ICON control by Resideo, V1.

A gas valve electronic fault has been detected.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

  1. Bradford White says to turn the set point knob to OFF, then to PILOT, and light the pilot, following the lighting instructions.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • verify the control is not wet or physically damaged; replace the gas valve if the seven-flash error persists.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 7 red blinks every 3 seconds (The combination gas control (thermostat) has failed.); A.O. Smith: 7 flashes, then a pause (Gas control valve/thermostat failure (State’s handbook: “internal control failure”).).

Source:

On its own page: 7 flashes, then a 3-second pause

8 flashes, then a 3-second pause

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

A false pilot flame is present: the pilot valve is stuck in the open position.

Bradford White gas control: 8 flashes, then a pause, repeating
Our drawing of a gas control valve: 8 flashes, then a pause, repeating.

What you see: 8 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means

The manual’s wording: “Eight flashes and three second pause” — ICON control by Resideo, V1.

A false pilot flame is present: the pilot valve is stuck in the open position.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

What Bradford White tells the owner to do

  1. Bradford White says to turn the set point knob to OFF, then to PILOT, and light the pilot, following the lighting instructions.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • replace the gas valve if the eight-flash error persists.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 8 red blinks every 3 seconds (Flame sense error.); A.O. Smith: 8 flashes, then a pause (This appears only after the gas control knob has been turned off: either the thermopile kept making power because it did not cool as quickly as expected, or the pilot kept burning because the pilot valve is stuck open.).

Source:

On its own page: 8 flashes, then a 3-second pause

9 red flashes, then a 3-second pause (Ultra Low NOx)

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

Tank leakage has been detected by an accessory module. The control recovers after it receives a message from the accessory module.

Bradford White gas control: 9 flashes, then a pause, repeating
Our drawing of a gas control valve: 9 flashes, then a pause, repeating.

What you see: 9 flashes, then a pause, repeating. Applies to: Bradford White Ultra Low NOx residential gas tank water heaters with the ICON System electronic gas control.

What it means

The manual’s wording: “Nine flashes and three second pause (LED red)” — ICON control by Resideo, V2, on Ultra Low NOx models.

Tank leakage has been detected by an accessory module. The control recovers after it receives a message from the accessory module.

Source: Ultra Low NOx Gas Water Heater Installation and Operation Manual (238-53393-00K, REV 08/26), “Troubleshooting — Resideo V1” and “Troubleshooting — Resideo V2”.

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 9 red blinks every 3 seconds (Low NOx models) (Chamber sensor failure: the sensor that watches the combustion chamber has failed.).

Source:

10 red flashes, then a 3-second pause (Ultra Low NOx)

If you smell gas: stop, and follow Bradford White’s own lines at the top of this page first

An abnormal combustion chamber temperature profile was seen during the heating cycle.

Bradford White gas control: 10 flashes, then a pause, repeating
Our drawing of a gas control valve: 10 flashes, then a pause, repeating.

What you see: 10 flashes, then a pause, repeating. Applies to: Bradford White Ultra Low NOx residential gas tank water heaters with the ICON System electronic gas control.

What it means

The manual’s wording: “Ten flashes and three second pause (LED red)” — ICON control by Resideo, V2, on Ultra Low NOx models.

An abnormal combustion chamber temperature profile was seen during the heating cycle.

Source: Ultra Low NOx Gas Water Heater Installation and Operation Manual (238-53393-00K, REV 08/26), “Troubleshooting — Resideo V1” and “Troubleshooting — Resideo V2”.

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • clean all combustion air intakes to the appliance; clean the burner; remove all obstacles that may restrict air flow to the burner.

When to call a qualified service agency: Bradford White’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 10 red blinks every 3 seconds (Low NOx models) (Chamber temperature shutdown: the combustion chamber got too hot and the heater shut down.).

Source:

On its own page: 10 red flashes, then a 3-second pause (Ultra Low NOx)

When to call a qualified service agency

Bradford White’s manual: “CAUTION: For your safety, do not attempt repair of combination gas control, burners or gas piping. Refer repairs to a qualified service technician.” Its FAQ adds: “If you are experiencing operating issues with your water heater, please contact a plumbing professional.”

semiatic gives no repair instructions of its own. The steps above are only the ones Bradford White addresses to the owner in its manual.