Rheem gas water heater: what the status light means

If you smell gas

Stop: do not relight or troubleshoot anything. Rheem’s own words (first page of both Use & Care Manuals, AP23060 and the Low NOx AP23698):

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.
  • Do not return to your home until authorized by the gas supplier or fire department.

Calling from a neighbor’s phone means leaving the building first.

Rheem’s atmospheric (standard-vent) gas tank water heaters with a diagnostic gas control show one status light on the front of the combination gas control, next to the temperature knob. Rheem’s Use & Care manual for its FVIR residential gas heaters gives a status light chart: one blue blink every three seconds is normal, and red blinks — 2, 4, 5, 7 or 8 per cycle, plus 9 and 10 on the Low NOx models — are faults. The label on the control itself says: if the status light blinks red more than one flash every three seconds, see the Use & Care manual.

The status light is on the combination gas control (thermostat), the box on the front of the tank near the bottom with the temperature knob and the spark (igniter) button below it. Rheem’s label notes that when the knob is turned to OFF with the pilot lit, the light stays lit briefly and turns from blue to red. The model and serial number are on the rating plate on the tank.

10 patterns, in blink order. Each has our drawing, Rheem’s meaning, the steps it gives the owner and its source. Find the brand and model on the rating plate first: the same count means different things on different makers’ heaters.

Status light off

If you smell gas: stop, and follow Rheem’s own lines at the top of this page first

The combination gas control is turned off, or the pilot is not lit, so there is no millivolt power from the thermopile to light the status light.

Rheem gas control: the status light is off
Our drawing of a gas control valve: the status light is off.

What you see: the status light is off. Applies to: Rheem residential atmospheric gas water heaters, 29 to 60 gallons, natural or LP gas — the manual linked from the Rheem Performance atmospheric XG40T06EC36U1 product page.

What it means

The manual’s wording: “OFF” — Rheem FVIR atmospheric models (AP23060).

The combination gas control is turned off, or the pilot is not lit, so there is no millivolt power from the thermopile to light the status light.

Source: Use & Care Manual with Installation Instructions — Water Heaters, Residential Gas, FVIR Certified (AP23060 Rev 01), “Combination Gas Control, Status Light Troubleshooting”.

What Rheem tells the owner to do

  1. Rheem says to follow the operating instructions in the Use & Care manual to turn on the combination gas control.
  2. Rheem says to light the pilot following the lighting instructions on the water heater and in its Use & Care manual.
  3. Rheem says to check that the thermopile connector is properly connected to the combination gas control.

The repair Rheem’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Rheem reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • check the thermopile wires for damage and replace them if needed; inspect the pilot assembly.

When to call a qualified service agency: Rheem’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: A.O. Smith: Status light off (0 flashes) (The pilot light is not lit, or there is not enough power (millivolts) from the thermopile to keep it lit.); Bradford White: LED off, not flashing (Millivolt power is not present: the pilot is out, so the gas valve is not powered.).

Source:

On its own page: Status light off

Status light on steady

If you smell gas: stop, and follow Rheem’s own lines at the top of this page first

The pilot was recently put out and the thermopile is cooling down, or the temperature knob was recently turned to OFF. Rheem’s label adds that the light stays lit briefly, turning from blue to red, when the knob is turned to OFF with the pilot lit. Not a fault.

Rheem gas control: the status light is on steady, not flashing
Our drawing of a gas control valve: the status light is on steady, not flashing.

What you see: the status light is on steady, not flashing. Applies to: Rheem residential atmospheric gas water heaters, 29 to 60 gallons, natural or LP gas — the manual linked from the Rheem Performance atmospheric XG40T06EC36U1 product page.

What it means

The manual’s wording: “Constantly lit” — Rheem FVIR atmospheric models (AP23060).

The pilot was recently put out and the thermopile is cooling down, or the temperature knob was recently turned to OFF. Rheem’s label adds that the light stays lit briefly, turning from blue to red, when the knob is turned to OFF with the pilot lit.

Not a fault.

Source: Use & Care Manual with Installation Instructions — Water Heaters, Residential Gas, FVIR Certified (AP23060 Rev 01), “Combination Gas Control, Status Light Troubleshooting”.

What Rheem tells the owner to do

  1. Rheem says to follow the lighting instructions on the water heater and in its Use & Care manual to light the pilot.

This pattern is normal operation. If the light shows a fault code instead, or you have no hot water with the light normal and the knob set correctly, call a qualified service agency: Rheem’s service line, below.

The same pattern on other brands — the same count on another maker’s gas control can mean something else: A.O. Smith: Status light on solid (The pilot was lit but is now off, and the thermopile is still cooling down.); Bradford White: LED on steady (The set point knob has recently been turned to OFF.).

Source:

On its own page: Status light on steady

When to call a qualified service agency

Rheem’s manual: “CAUTION: For your safety DO NOT attempt repair of gas piping, Combination Gas Control (Thermostat), burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.” For service it says to contact your installer, plumbing contractor or previously agreed upon service agency first, then Rheem’s national service department on 1-800-432-8373 with the model and serial number from the rating plate.

semiatic gives no repair instructions of its own. The steps above are only the ones Rheem addresses to the owner in its manual.