A.O. Smith and State gas water heater: what the status light means
If you smell gas
Stop: do not relight or troubleshoot anything. A.O. Smith’s own words (Residential Gas Water Heater Installation Instructions and Use & Care Guide 100263112, cover page):
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
Calling from a neighbor’s phone means leaving the building first.
A.O. Smith’s standard atmospheric gas water heaters with the flammable-vapor-resistant (FVIR) system have an electronic gas control valve powered by a thermopile in the pilot flame, with a status light on the valve. Its Use & Care Guide says the light flashes once every three seconds when the pilot is lit and the valve has found no problem; more flashes than that are a code from its Status Light Code Troubleshooting Chart: 2, 4, 5, 7 or 8. State, another A.O. Smith brand, prints the same codes with the same meanings in its service handbook for residential standard gas water heaters, so each code has one page here.
The status light is on the gas control valve, the box on the front of the tank with the gas control knob (OFF, PILOT and temperature settings) and the igniter button. The model and serial number are on the water heater’s data plate. A.O. Smith’s own pilot-lighting article says the light must flash once per second, while the Use & Care Guide’s chart says once every three seconds; these pages follow the chart in the manual, which is the one that lists the codes.
8 patterns, in blink order. Each has our drawing, A.O. Smith’s meaning, the steps it gives the owner and its source. Find the brand and model on the rating plate first: the same count means different things on different makers’ heaters.
Status light off (0 flashes)
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
The pilot light is not lit, or there is not enough power (millivolts) from the thermopile to keep it lit.
What you see: the status light is off. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “0 FLASHES (LED NOT LIT)” — A.O. Smith and State electronic gas control valve.
The pilot light is not lit, or there is not enough power (millivolts) from the thermopile to keep it lit.
What A.O. Smith tells the owner to do
- A.O. Smith says to follow the lighting instructions on the front of the water heater and record any diagnostic codes.
- A.O. Smith says a lighting attempt means holding the knob in at PILOT and clicking the igniter about once a second for up to 90 seconds; if the light has not started flashing, release the knob and wait 10 minutes before trying again, for at least three attempts in all.
- A.O. Smith says that if the light still has not started flashing after three attempts, turn the gas control knob to OFF; if the pilot still will not light, call a qualified person.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: Status light off (The combination gas control is turned off, or the pilot is not lit, so there is no millivolt power from the thermopile to light the status light.); Bradford White: LED off, not flashing (Millivolt power is not present: the pilot is out, so the gas valve is not powered.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
Status light on solid
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
The pilot was lit but is now off, and the thermopile is still cooling down. The valve will not relight until it has cooled.
What you see: the status light is on steady, not flashing. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “A solid Status Light” — A.O. Smith and State electronic gas control valve.
The pilot was lit but is now off, and the thermopile is still cooling down. The valve will not relight until it has cooled.
What A.O. Smith tells the owner to do
- A.O. Smith says to release the gas control knob and wait 10 minutes; once the status light goes out, light the pilot again following the lighting instructions.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: Status light on steady (The pilot was recently put out and the thermopile is cooling down, or the temperature knob was recently turned to OFF.); Bradford White: LED on steady (The set point knob has recently been turned to OFF.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
1 flash every 3 seconds
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
Normal operation: the pilot is lit and the gas control valve has not detected any problem. No corrective action is needed. Not a fault.
What you see: one flash, then a pause, repeating. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “1 FLASH (EVERY 3 SECONDS)” — A.O. Smith and State electronic gas control valve.
Normal operation: the pilot is lit and the gas control valve has not detected any problem. No corrective action is needed.
Not a fault.
What A.O. Smith tells the owner to do
- A.O. Smith says that if the light flashes once every three seconds and you have no hot water, make sure the gas control knob is set to HOT.
This pattern is normal operation. If the light shows a fault code instead, or you have no hot water with the light normal and the knob set correctly, call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 1 blue blink every 3 seconds (Normal operation: the pilot is lit.); Bradford White: 1 flash, then a pause of 3 to 4 seconds (No fault.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
2 flashes, then a pause
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
Insufficient power (millivolts) reaching the gas control valve/thermostat from the thermopile.
What you see: 2 flashes, then a pause, repeating. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “2 FLASHES” — A.O. Smith and State electronic gas control valve.
Insufficient power (millivolts) reaching the gas control valve/thermostat from the thermopile.
What A.O. Smith tells the owner to do
A.O. Smith’s manual gives the owner no step of their own for this code: call for service.
The repair A.O. Smith’s table gives — for the qualified person you call
Shown so you know what to expect, not as steps to do yourself: A.O. Smith reserves repairs to the gas control, burner and gas piping for a qualified service technician.
- check all wiring connections; if the problem persists, replace the thermopile.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 2 red blinks every 3 seconds (Low thermopile voltage, although the pilot is lit.); Bradford White: 2 flashes, then a 3-second pause (Weak pilot flame detected.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
4 flashes, then a pause
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
High water temperature has activated the overheat sensor (State’s handbook calls it “temperature exceeded (ECO activated)”). The heater shuts down.
What you see: 4 flashes, then a pause, repeating. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “4 FLASHES” — A.O. Smith and State electronic gas control valve.
High water temperature has activated the overheat sensor (State’s handbook calls it “temperature exceeded (ECO activated)”). The heater shuts down.
What A.O. Smith tells the owner to do
A.O. Smith’s manual gives the owner no step of their own for this code: call for service.
The repair A.O. Smith’s table gives — for the qualified person you call
Shown so you know what to expect, not as steps to do yourself: A.O. Smith reserves repairs to the gas control, burner and gas piping for a qualified service technician.
- replace the gas control valve/thermostat.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 4 red blinks every 3 seconds (The high water temperature limit has tripped: the water got hotter than the control’s safety limit, and the heater has shut down.); Bradford White: 4 flashes, then a 3-second pause (Excessive tank temperature.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
5 flashes, then a pause
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
Sensor failure: the temperature sensor in the gas control valve has failed.
What you see: 5 flashes, then a pause, repeating. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “5 FLASHES” — A.O. Smith and State electronic gas control valve.
Sensor failure: the temperature sensor in the gas control valve has failed.
What A.O. Smith tells the owner to do
A.O. Smith’s manual gives the owner no step of their own for this code: call for service.
The repair A.O. Smith’s table gives — for the qualified person you call
Shown so you know what to expect, not as steps to do yourself: A.O. Smith reserves repairs to the gas control, burner and gas piping for a qualified service technician.
- replace the gas control valve/thermostat.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 5 red blinks every 3 seconds (Water temperature sensor failure.); Bradford White: 5 flashes, then a 3-second pause (Temperature sensor fault.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
7 flashes, then a pause
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
Gas control valve/thermostat failure (State’s handbook: “internal control failure”).
What you see: 7 flashes, then a pause, repeating. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “7 FLASHES” — A.O. Smith and State electronic gas control valve.
Gas control valve/thermostat failure (State’s handbook: “internal control failure”).
What A.O. Smith tells the owner to do
A.O. Smith’s manual gives the owner no step of their own for this code: call for service.
The repair A.O. Smith’s table gives — for the qualified person you call
Shown so you know what to expect, not as steps to do yourself: A.O. Smith reserves repairs to the gas control, burner and gas piping for a qualified service technician.
- replace the gas control valve/thermostat.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 7 red blinks every 3 seconds (The combination gas control (thermostat) has failed.); Bradford White: 7 flashes, then a 3-second pause (A gas valve electronic fault has been detected.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
8 flashes, then a pause
If you smell gas: stop, and follow A.O. Smith’s own lines at the top of this page first
This appears only after the gas control knob has been turned off: either the thermopile kept making power because it did not cool as quickly as expected, or the pilot kept burning because the pilot valve is stuck open.
What you see: 8 flashes, then a pause, repeating. Applies to: A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. State heaters use the same codes.
What it means
The manual’s wording: “8 FLASHES” — A.O. Smith and State electronic gas control valve.
This appears only after the gas control knob has been turned off: either the thermopile kept making power because it did not cool as quickly as expected, or the pilot kept burning because the pilot valve is stuck open.
What A.O. Smith tells the owner to do
- A.O. Smith says to make sure the gas control knob is set to OFF, wait one minute, and look through the sight glass for a pilot flame.
- A.O. Smith says that if a pilot flame is burning with the knob at OFF, the pilot valve is stuck open: turn the main gas supply OFF.
- A.O. Smith says that if there is no pilot flame with the knob at OFF, wait 10 minutes for the thermopile to cool, then relight the pilot following the lighting instructions on the water heater’s label.
The repair A.O. Smith’s table gives — for the qualified person you call
Shown so you know what to expect, not as steps to do yourself: A.O. Smith reserves repairs to the gas control, burner and gas piping for a qualified service technician.
- replace the gas control valve/thermostat if the pilot valve is stuck open, or if the condition returns after relighting.
When to call a qualified service agency: A.O. Smith’s service line, below.
The same pattern on other brands — the same count on another maker’s gas control can mean something else: Rheem: 8 red blinks every 3 seconds (Flame sense error.); Bradford White: 8 flashes, then a 3-second pause (A false pilot flame is present: the pilot valve is stuck in the open position.).
Source:
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.
On its own page: 8 flashes, then a pause
When to call a qualified service agency
A.O. Smith’s manual: “Installation and service must be performed by a qualified installer, service agency or the gas supplier.” Its Technical Assistance Hotline is 1-800-527-1953; have the model and serial number from the data plate ready.
semiatic gives no repair instructions of its own. The steps above are only the ones A.O. Smith addresses to the owner in its manual.
Sources
A.O. Smith’s own manuals and pages only, read on the date shown. Nothing here comes from forums or third-party “codes explained” sites.
- A.O. Smith: Residential Gas Water Heater Installation Instructions and Use & Care Guide (100263112, January 2015), “Status Light Code Troubleshooting Chart” and “Lighting the Pilot” — A.O. Smith residential atmospheric gas water heaters with the Flammable Vapor Ignition Resistant safety system and an electronic gas control valve. assets.hotwater.com Checked 2026-09-29.
- State Water Heaters (A.O. Smith): Residential Standard Gas Water Heater Service Handbook (327306), “Diagnostic Flash Codes” — State residential standard (atmospheric) gas water heaters with the electronic gas control valve/thermostat — a handbook written for qualified service professionals. www.statewaterheaters.com Checked 2026-09-29.