Gas water heater status light blinking: what Rheem, A.O. Smith and Bradford White codes mean

32 status-light patterns for US gas tank water heaters, from the makers’ own manuals. One flash, then a pause, is normal on all three brands. 4 flashes is an overheat shutdown on all three. But the counts do not always agree: 6 flashes on a Bradford White means a water leak on its Resideo V1 control and a failed door temperature sensor on the Ultra Low NOx Resideo V2, and 9 or 10 flashes exist only on Rheem and Bradford White Low NOx models. Pick the brand and the count.

What people ask

Status light blinking 7 times? On all three makes 7 flashes is a fault in the gas control itself: Rheem’s chart says “Combination Gas Control (Thermostat) failure”, A.O. Smith/State’s “Internal control failure”, Bradford White’s Resideo V1 table “Gas valve electronic fault detected”. Each maker’s remedy ends in replacing the gas control valve, a job for a qualified service technician, not the owner. By make: Rheem, 7 red blinks every 3 seconds · A.O. Smith, 7 flashes, then a pause · Bradford White, 7 flashes, then a 3-second pause.
Sources: Rheem, Use & Care manual, Low NOx atmospheric gas water heaters: status light codes chart and label Checked 2026-10-10. · State (A.O. Smith), Residential standard gas water heater service handbook: diagnostic flash codes Checked 2026-10-10. · Bradford White, Installation and operating instructions, gas water heaters with the ICON System: troubleshooting charts Checked 2026-10-10.

5 more: 4 flashes, blinking once, blue or green, 2 flashes, light off, relighting the pilot

Blinking 4 times? An overheat shutdown on all three: Rheem “High water temperature limit tripped”, A.O. Smith/State “Temperature exceeded (ECO activated)”, Bradford White “Excessive tank temperature” (V1) or “Temperature cut-out limit reached, causing shutdown” (V2). Bradford White’s V1 table adds “System must be reset” and blames a temperature sensor out of calibration or a faulty gas valve; Rheem’s chart sends you to its “If you need service” section, and A.O. Smith/State’s fix is a new gas control valve. Treat it as a call for a technician, not a button to press. By make: Rheem, 4 red blinks every 3 seconds · A.O. Smith, 4 flashes, then a pause · Bradford White, 4 flashes, then a 3-second pause.
Sources: Rheem, Use & Care manual, Low NOx atmospheric gas water heaters: status light codes chart and label Checked 2026-10-10. · State (A.O. Smith), Residential standard gas water heater service handbook: diagnostic flash codes Checked 2026-10-10. · Bradford White, Installation and operating instructions, gas water heaters with the ICON System: troubleshooting charts Checked 2026-10-10.

Blinking once, blue or green: is that normal? Yes. One flash, then a pause, means the pilot is lit and nothing is wrong: Rheem’s label shows it as one blue blink every three seconds, A.O. Smith’s guide as one flash every three seconds, and Bradford White’s Resideo V2 table as one green flash every four seconds (“Not an error”); a green flash every second there means the burner is on. Rheem’s label adds: “If Status Light blinks red more than one flash every three seconds, see Use & Care Manual.” By make: Rheem, 1 blue blink every 3 seconds · A.O. Smith, 1 flash every 3 seconds · Bradford White, 1 flash, then a pause of 3 to 4 seconds.
Sources: Rheem, Use & Care manual, Low NOx atmospheric gas water heaters: status light codes chart and label Checked 2026-10-10. · A.O. Smith, Residential standard gas water heater Use and Care Guide: lighting and no hot water Checked 2026-10-10. · Bradford White, Installation and operating instructions, gas water heaters with the ICON System: troubleshooting charts Checked 2026-10-10.

Blinking twice? Low power from the pilot’s thermopile on all three: Rheem “Low thermopile voltage however pilot is lit”, A.O. Smith/State “Thermopile voltage low”, Bradford White “Weak pilot flame detected” (V1) or “Low thermopile voltage; main valve not turned ON” (V2, yellow). The makers’ checks are the thermopile wiring and the pilot flame. By make: Rheem, 2 red blinks every 3 seconds · A.O. Smith, 2 flashes, then a pause · Bradford White, 2 flashes, then a 3-second pause.
Sources: Rheem, Use & Care manual, Low NOx atmospheric gas water heaters: status light codes chart and label Checked 2026-10-10. · State (A.O. Smith), Residential standard gas water heater service handbook: diagnostic flash codes Checked 2026-10-10. · Bradford White, Installation and operating instructions, gas water heaters with the ICON System: troubleshooting charts Checked 2026-10-10.

Status light off, or not blinking at all? No light means the control has no power from the pilot: Rheem’s and A.O. Smith/State’s charts both read “Control Off/Pilot Out”, Bradford White’s “Millivolt power is not present. Light pilot.” A.O. Smith’s guide says to try lighting the pilot by its lighting instructions, and to call a qualified person if it still will not light. By make: Rheem, Status light off · A.O. Smith, Status light off (0 flashes) · Bradford White, LED off, not flashing.
Sources: Rheem, Use & Care manual, Low NOx atmospheric gas water heaters: status light codes chart and label Checked 2026-10-10. · State (A.O. Smith), Residential standard gas water heater service handbook: diagnostic flash codes Checked 2026-10-10. · A.O. Smith, Residential standard gas water heater Use and Care Guide: lighting and no hot water Checked 2026-10-10. · Bradford White, Installation and operating instructions, gas water heaters with the ICON System: troubleshooting charts Checked 2026-10-10.

How do I relight it after the pilot went out? If you smell gas, do not relight anything: leave and call your gas supplier from a neighbor’s phone. Otherwise wait out the steady light: A.O. Smith says “A solid Status Light means the pilot was lit but is now out” and to wait 10 minutes until it goes out, Bradford White to “Wait until LED goes out before attempting to relight”; then follow the lighting instructions on the heater’s label, which on A.O. Smith means holding the knob in for up to 90 seconds until the light flashes once every three seconds. By make: Rheem, Status light on steady · A.O. Smith, Status light on solid · Bradford White, LED on steady.
Sources: A.O. Smith, Residential standard gas water heater Use and Care Guide: lighting and no hot water Checked 2026-10-10. · Bradford White, Installation and operating instructions, gas water heaters with the ICON System: troubleshooting charts Checked 2026-10-10.

The questions are Google’s search suggestions; each answer comes only from the maker manuals named under it.

If you smell gas: do not light any appliance or touch any electrical switch, and call your gas supplier from a neighbor’s phone — every maker’s manual below says so first, and every brand page here prints the maker’s own lines before anything else.

Find it by what you see

32 patterns.

Only Rheem (blue for normal, red for faults) and Bradford White’s Resideo V2 control (green, yellow, red) name colours; a light whose maker names no colour matches any colour you pick.

By brand

What these pages cannot do

Left out, and why

A brand gets pages when its own manual documents at least 5 status-light patterns and we could read them. Rheem, A.O. Smith (with State) and Bradford White did. These were not used: