semiatic

Bradford White gas water heater status light: 6 flashes, then a 3-second pause

ICON control by Resideo, V1: A water leak has been detected by an accessory module (some models only): an excessive amount of water in the drain pan or water dam.
ICON control by Resideo, V2, on Ultra Low NOx models: Door temperature sensor failure.

If you smell gas

Stop: do not relight or troubleshoot anything. Bradford White’s own words (first page of both Installation and Operation Manuals, 238-51007-00R and the Ultra Low NOx 238-53393-00K):

  • DO NOT try to light any appliance.
  • DO NOT touch any electrical switch.
  • DO NOT use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

Calling from a neighbor’s phone means leaving the building first.

×6, pause
Our drawing of a gas control valve: 6 flashes, then a pause, repeating.

Bradford White’s manual has 2 gas controls with a table for this pattern, and they do not all mean the same thing: the full wording for each is below.

What you see: 6 flashes, then a pause, repeating. Applies to: Bradford White residential gas-fired tank water heaters with the ICON System electronic gas control.

What it means, by gas control

ICON control by Resideo, V1

The manual’s wording: “Six flashes and three second pause”.

A water leak has been detected by an accessory module (some models only): an excessive amount of water in the drain pan or water dam.

Source: Gas-Fired Water Heater Installation and Operation Manual (238-51007-00R, REV 07/26), “Troubleshooting — ICON System Electronic Gas Control” (Resideo V1, Resideo V2, SIT).

ICON control by Resideo, V2, on Ultra Low NOx models

The manual’s wording: “Six flashes and three second pause (LED red)”.

Door temperature sensor failure.

Source: Ultra Low NOx Gas Water Heater Installation and Operation Manual (238-53393-00K, REV 08/26), “Troubleshooting — Resideo V1” and “Troubleshooting — Resideo V2”.

What Bradford White tells the owner to do

Bradford White’s manual gives the owner no step of their own for this code: call for service.

semiatic gives no repair instructions of its own. The steps above are only the ones Bradford White addresses to the owner in its manual.

The repair Bradford White’s table gives — for the qualified person you call

Shown so you know what to expect, not as steps to do yourself: Bradford White reserves repairs to the gas control, burner and gas piping for a qualified service technician.

  • ICON control by Resideo, V2, on Ultra Low NOx models: check the door temperature sensor and its connection for open circuits or shorts.

When to call a qualified service agency

Bradford White’s manual: “CAUTION: For your safety, do not attempt repair of combination gas control, burners or gas piping. Refer repairs to a qualified service technician.” Its FAQ adds: “If you are experiencing operating issues with your water heater, please contact a plumbing professional.”

Source

Bradford White’s own manuals, read on the date shown.

Other Bradford White status lights