Toshiba error codes
30 codes that Toshiba publishes for an air conditioner and a heat pump, each quoted from the maker’s own manual or support page and explained on its appliance’s page. Pick the appliance, or type the code from the display: only Toshiba codes are searched here.
Every Toshiba appliance we cover
| Appliance | Codes | Source |
|---|---|---|
| Toshiba air conditioner | 12 codes | Toshiba, 1 document |
| Toshiba heat pump | 18 codes | Toshiba, 2 documents |
Toshiba air conditioner error codes
12 codes from Toshiba. 12 of them are marked for an installer; for the rest the page gives the checks the maker lets an owner do. Tap a code for its meaning:
Toshiba heat pump error codes
18 codes from Toshiba. 18 of them are marked for an installer; for the rest the page gives the checks the maker lets an owner do. Tap a code for its meaning:
The same Toshiba code on more than one appliance
Toshiba uses these codes on more than one of its appliances. Read the one for your machine: the cause and what you can check are the maker’s for that appliance, and they can differ even where the fault sounds alike.
E04: air conditioner — indoor–outdoor communication error; heat pump — indoor and outdoor unit not communicating.E03: air conditioner — indoor unit not hearing the remote controller; heat pump — remote controller not communicating.H01: air conditioner — compressor breakdown; heat pump — compressor breakdown or lock.H02: air conditioner — compressor locked; heat pump — compressor breakdown or lock.
Air conditioner: do only the checks the maker gives the owner for that code — clean the air filter, clear the air path, switch the power off and on at the plug or circuit breaker. Keep the covers on: refrigerant, wiring and circuit boards are not owner work. Anything else is for the installer or the maker’s service engineer: in the UK and EU only an F-gas certified technician may open the refrigerant circuit. Heat pump: do only the checks the maker gives the owner for that code — read the water pressure on the controller, keep the outdoor unit clear of leaves and snow, switch the power off and on where the maker says to. Keep the casing on: refrigerant, wiring and the water circuit’s parts are not owner work. Anything else is for the heat-pump installer or the maker’s service engineer: in the UK and EU only an F-gas certified technician may open the refrigerant circuit. Two Toshiba models can use different codes: your model’s manual is the authority.
Sources
Every Toshiba code on this site comes from these pages, published by Toshiba and read on the date shown.
- Toshiba (air conditioner): Toshiba — Installation Manual, High-Wall Type Indoor Unit RAV-HM1101KRTP-E (R32, 2024-04-29): Troubleshooting, Error codes and parts to be checked Checked 2026-09-29.
- Toshiba (heat pump): Installation Manual, Air to Water Heat Pump, Hydro Unit wall mounted type HWT-601/1101/1401XWHM3W/M6W/T6W/T9W-E, R32 (2F30151001-05, 2023-02-17): Troubleshooting, failure mode detected by the Hydro Unit Checked 2026-10-13.
- Toshiba (heat pump): Owner’s Manual, Air to Water Heat Pump, Hydro Unit wall mounted type HWT-601/1101/1401XWH (2F30152001-04, 2023-02-08): 6 Troubleshooting Checked 2026-10-13.