Daikin heat pump error codes
18 codes that Daikin Europe publishes for its heat pumps, each with what it means, the likely cause, what you can safely check and when to call an installer. Tap your code:
What people ask
Where does a Daikin Altherma show its fault code, and how do I read it? A fault puts a symbol on the user interface’s home screen; Daikin’s steps are “Press the left dial to open the main menu and go to Malfunctioning”, and then “A short description of the error and the error code is displayed on the screen”. A further press in that error screen gives “A long description of the error”. If the user permission level is set to advanced end user, Information › Malfunction history shows “a list of the most recent malfunctions”.
Source: Daikin Europe, Operation manual, Daikin Altherma 3 H MT F+W (4P634883-2C, 2022.08): 4.3 Domestic hot water, 5.1 User interface: Overview, 5.3 Possible screens, 8 Troubleshooting Checked 2026-10-13.
What does U3 mean on a Daikin heat pump? Daikin’s installer guide for the Altherma 3 H MT F lists U3-00 as “Underfloor heating screed dryout function not completed correctly”, and says “When the program is stopped by an error or an operation switch off, the U3 error will be displayed on the user interface.” A power cut does not cause it: “In case of a power failure, the U3 error is not generated”, and the unit restarts the latest step when power returns. That guide lists U3-00 only; the U3-02 to U3-10 codes also searched are not in it. On this page: U3-00 screed dry-out not completed.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F (4P634887-1, 2021.03): UFH screed dryout (p. 217) and 14.4 Solving problems based on error codes (pp. 234–238) Checked 2026-10-13.
3 more: AH-00, the symbol and red light, resetting a code
What does AH-00 mean on a Daikin Altherma? The installer guide lists AH-00 among the unit’s error codes as “Tank disinfection function not completed correctly”, and the operation manual names one cause you control: tank heating can be switched off, “However, if you turn it OFF while disinfection is running, an AH error occurs.” Where no hot-water tapping interrupted the run, the installer guide recommends setting the disinfection start “at least 4 hours later than the last expected large hot water tapping” — an installer setting. On this page: AH-00 tank disinfection not completed.
Sources: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F (4P634887-1, 2021.03): UFH screed dryout (p. 217) and 14.4 Solving problems based on error codes (pp. 234–238) Checked 2026-10-13. · Daikin Europe, Operation manual, Daikin Altherma 3 H MT F+W (4P634883-2C, 2022.08): 4.3 Domestic hot water, 5.1 User interface: Overview, 5.3 Possible screens, 8 Troubleshooting Checked 2026-10-13.
What do the error symbol and the blinking red light on a Daikin Altherma mean? Daikin’s operation manual: “In case of a malfunction, the following will appear on the home screen depending on the severity” — one symbol for “Error”, another for “Malfunction”. The status indicator says the same thing: “Blinking red” means “A malfunction occurred.” In both cases the code is under Malfunctioning in the main menu, an entry Daikin marks “Only displayed if a malfunction occurs.”
Source: Daikin Europe, Operation manual, Daikin Altherma 3 H MT F+W (4P634883-2C, 2022.08): 4.3 Domestic hot water, 5.1 User interface: Overview, 5.3 Possible screens, 8 Troubleshooting Checked 2026-10-13.
Can I reset a Daikin heat pump error code myself? Daikin’s installer guide: “It is important to understand the problem and to take measures before resetting an error code. This should be done by a licensed installer or by your local dealer.” Some codes clear themselves — below a 20 l/min water flow the unit stops with 7H-01, and “After some time, this error will reset automatically and the unit will resume operation” — and otherwise “The user interface will display how to reset an error code.” The operation manual adds: “For any other problem, contact your installer. You can find the contact/helpdesk number via the user interface” (Information › Dealer information). On this page: 7H-01 water flow problem.
Sources: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F (4P634887-1, 2021.03): UFH screed dryout (p. 217) and 14.4 Solving problems based on error codes (pp. 234–238) Checked 2026-10-13. · Daikin Europe, Operation manual, Daikin Altherma 3 H MT F+W (4P634883-2C, 2022.08): 4.3 Domestic hot water, 5.1 User interface: Overview, 5.3 Possible screens, 8 Troubleshooting Checked 2026-10-13.
The questions are the ones people search for Daikin heat pump codes; each answer comes only from the Daikin Europe pages named under it.
Heat pump: do only the checks the maker gives the owner for that code — read the water pressure on the controller, keep the outdoor unit clear of leaves and snow, switch the power off and on where the maker says to. Keep the casing on: refrigerant, wiring and the water circuit’s parts are not owner work. Anything else is for the heat-pump installer or the maker’s service engineer: in the UK and EU only an F-gas certified technician may open the refrigerant circuit. Codes that need one are marked Installer.
Read this first
Daikin Altherma 3 heat pumps show a fault on the user interface as two characters, a dash and two digits — 7H-01, U4-00, AH-00 — with a warning or error symbol on the home screen. To read it, press the left dial, go to Malfunctioning, and press again for Daikin’s own long description of the fault. The codes here come from the installer reference guide for the Altherma 3 H MT F (EPRA outdoor units with ETVZ indoor units); the owner’s steps come from the operation manual of the Altherma 3 H MT F+W. Models differ: your model’s manual is the authority. Daikin says the problem should be understood and fixed before an error code is reset, by a licensed installer or your dealer.
7H-01 7H-05 Water flow problem
- What it means
- Too little water is flowing through the heat pump: 7H-01 in general, 7H-05 during heating. Related sub-codes are 7H-04 (hot-water production), 7H-06 (cooling or defrost), 7H-07 (pump deblocking active) and 7H-08 (pump abnormality).
- Likely cause
- Daikin’s installer guide, for a water flow that is too low, lists: closed shut-off valves, dirty water filters, air in the system, water pressure at or below 1 bar, a broken expansion vessel, or too high a resistance for the pump.
- What you can safely check
Heat pump: do only the checks the maker gives the owner for that code — read the water pressure on the controller, keep the outdoor unit clear of leaves and snow, switch the power off and on where the maker says to. Keep the casing on: refrigerant, wiring and the water circuit’s parts are not owner work.
- Read the water pressure on the user interface’s home screen. Daikin asks owners to check regularly that it is above 1 bar.
- When to call an installer
- Call your installer: the valves, filters, air purge and pump are theirs to check. Tell them the pressure you read.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
AH-00 Tank disinfection not completed
- What it means
- The domestic hot-water tank’s disinfection (anti-legionella) run did not finish correctly.
- Likely cause
- The operation manual gives one owner cause: turning tank heating off while disinfection is running causes an AH error. A large hot-water draw during the run can interrupt it too.
- What you can safely check
Heat pump: do only the checks the maker gives the owner for that code — read the water pressure on the controller, keep the outdoor unit clear of leaves and snow, switch the power off and on where the maker says to. Keep the casing on: refrigerant, wiring and the water circuit’s parts are not owner work.
- Leave tank heating on while a disinfection run is in progress (the tank screen shows it). Turning tank heating off does not stop disinfection mode, but switching it off mid-run triggers AH.
- When to call an installer
- If AH returns without that, ask your installer to move the disinfection start to at least 4 hours after your last large hot-water use — Daikin’s own recommendation.
Source: Daikin Europe, Operation manual, Daikin Altherma 3 H MT F+W ETVH/X12, ETBH/X12 (4P634883-2C, 2022.08): 7 Maintenance, 8 Troubleshooting Checked 2026-09-29.
U4-00 Indoor and outdoor unit not communicating
- What it means
- The indoor unit and the outdoor unit have lost communication.
- Likely cause
- The communication wiring, power to the outdoor unit, or a circuit board.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
U0-00 Refrigerant shortage
- What it means
- The outdoor unit has detected a shortage of refrigerant.
- Likely cause
- Too little refrigerant — usually a leak.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer: only an F-gas certified technician may find a leak and recharge the refrigerant.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
U2-00 Power supply voltage fault
- What it means
- The outdoor unit has detected a defect in the supply voltage.
- Likely cause
- An abnormal supply voltage or wiring fault.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
U3-00 Screed dry-out not completed
- What it means
- The underfloor-heating screed dry-out programme, run to dry a new floor slowly, did not finish correctly.
- Likely cause
- The dry-out programme was interrupted.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer: the dry-out programme is set and restarted from the installer menus.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
89-02 Heat exchanger freeze-up protection
- What it means
- Freeze-up protection of the heat exchanger activated during heating or hot-water production (89-01 and 89-03 are the same during defrost).
- Likely cause
- The water side of the heat exchanger got close to freezing; Daikin’s list gives no further cause for owners.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
80-01 81-00 Water temperature sensor problem
- What it means
- 80-01: the returning-water temperature sensor; 81-00: the leaving-water temperature sensor.
- Likely cause
- A faulty sensor or its wiring.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
HC-00 Tank temperature sensor problem
- What it means
- The domestic hot-water tank’s temperature sensor is giving no sensible reading.
- Likely cause
- A faulty sensor or its wiring.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
HJ-10 Water pressure sensor abnormality
- What it means
- The water pressure sensor is not working correctly.
- Likely cause
- A faulty pressure sensor or its wiring.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
AA-01 Backup heater overheated
- What it means
- The backup heater has overheated, or its power cable is not connected.
- Likely cause
- An overheated backup heater or a missing power connection.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer: the backup heater and its thermal cut-out are inside the indoor unit.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
E7-00 Outdoor fan motor fault
- What it means
- The outdoor unit’s fan motor has a malfunction.
- Likely cause
- A fan motor fault, or something stopping the fan.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
A5-00 High-pressure peak cut or freeze protection
- What it means
- An outdoor-unit protection: the high-pressure peak cut or the freeze protection has operated.
- Likely cause
- A pressure or temperature outside the unit’s limits in the refrigerant circuit.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
E1-00 Outdoor circuit board defect
- What it means
- The outdoor unit’s circuit board is defective.
- Likely cause
- A board fault.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
U8-02 U8-03 Room thermostat connection lost
- What it means
- U8-02: the connection with the room thermostat was lost; U8-03: there is no connection with it.
- Likely cause
- The room thermostat’s link (wiring, or the wireless receiver) to the heat pump.
- What you can safely check
Nothing for the owner to check: this one is for an installer.
- When to call an installer
- Installer Contact your installer.
Source: Daikin Europe, Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
A code that is not listed here
Daikin’s installer guide lists over 100 error codes, many of them sub-codes of one fault (7H-01 to 7H-08 are all water-flow problems). For a code not listed here, look at the long description under Malfunctioning, then contact your installer: the operation manual shows where to find their contact number (Information › Dealer information). If the heat pump has failed, the backup heater can take over heating and hot water, automatically or after you confirm it on the Malfunctioning screen — at a considerably higher electricity use.
We list only codes the source below states. If your code is not here, it may belong to a model the source does not cover: your model’s manual is the authority.
Related pages
Source
Every code on this page comes from these pages, published by Daikin Europe and read on the date shown. Meanings are written in our own words; nothing is taken from other makes, other models or third-party code sites.
- Daikin Europe: Installer reference guide, Daikin Altherma 3 H MT F EPRA08-12EAV3/W1 + ETVZ12E6V/9W (4P634887-1, 2021.03): 14.4 Solving problems based on error codes Checked 2026-09-29.
- Daikin Europe: Operation manual, Daikin Altherma 3 H MT F+W ETVH/X12, ETBH/X12 (4P634883-2C, 2022.08): 7 Maintenance, 8 Troubleshooting Checked 2026-09-29.