Lo on a thermometer (below the measuring range)
The thermometer measured something colder than the lowest temperature it is built to report, so it shows Lo instead of a number. Every manual read treats it as a measurement to take again, not as a result: they tell you to check the probe or sensor and how the thermometer was held, then measure again.
Check your thermometer’s manual — makers differ.
What it is for
Measure again, following your manual’s steps. Braun (ThermoScan): “Make sure the probe tip and lens are clean and a new, clean lens filter is attached. Make sure the thermometer is properly inserted. Then, take a new temperature.” Microlife (NC 200): “Make sure the measuring sensor is clean. Then, take a measurement again.” Omron (ET720): “Use the unit within its measurable range. If a malfunction still exists, please contact OMRON customer service.” Beurer (FT 95): “Operate the thermometer only within the specified temperature ranges.” If Lo appeared the moment you switched on a stick thermometer, wait instead: iProven (DT-K 117A / B): “When the letters ‘Lo’ and a flashing ‘ºC’ or ‘ºF’ displays for 5 seconds, the thermometer is ready for use.” Vicks (SpeedRead V912CA): “After about 5 seconds, the display will show it’s ready (Fig. 4).”
These pages report what each maker’s manual says and quote it wherever health is involved. They do not diagnose anything, they are not medical advice, and they do not tell you whether a temperature is a fever or what to do about it; only your own thermometer’s manual and your doctor or nurse can do that for the person you are looking after.
- What it looks like
- The letters Lo, LO or just L where the number would be. Some makers show a word or an error screen instead.
- Names makers use
- Lo (Omron ET720); LO (Braun ThermoScan); L (Microlife IR 310, NC 200 and MT 410); Error (Withings Thermo); An error screen (Beurer FT 90 and FT 95, Braun No touch BNT 400); Lo, which is also its ready screen (Vicks SpeedRead V912CA); Lo °C or Lo °F (iProven DT-K 117A / B); A display message the manual prints only as a picture (Exergen TemporalScanner TAT-2000C)
Where makes differ
Where the floor sits depends on the maker and the mode. Omron’s ET720 manual shows Lo below 93.2°F (34.0°C) on the forehead and below -7.6°F (-22°C) in surface mode. Braun’s ThermoScan manual shows LO below 34 °C (93.2 °F), and Beurer’s FT 95 manual gives its error below 34 °C on the forehead and below 0 °C in object mode. Microlife’s floor is lower on some models: its manuals give L below 32 °C on the IR 310 ear thermometer and the MT 410 stick thermometer, but below 34 °C in body mode on the NC 200. Withings’ Thermo shows the word Error below 35°C (95°F). On a Microlife MT 410 stick thermometer an L with a flashing °C is normal before you start: Microlife’s manual says it appears when the air is below 32°C, and that the thermometer “is now ready for use”. iProven’s DT-K 117A / B manual shows Lo °C or Lo °F when the temperature “is under 32 ºC or 89.6 ºF”, and iProven says the same Lo with a flashing °C or °F at switch-on means the thermometer is ready. Vicks’ SpeedRead V912CA manual uses Lo for its ready screen as well: it tells you to hold the power button “until ‘Lo’ (Fig. 4) appears”, and Fig. 4 is the screen it calls ready; the Temperature Range line we read gives the figure for Hi but none for Lo. Exergen’s TemporalScanner TAT-2000C reaches much lower: its manual lists its below-range display message for a temperature measured lower than 60 °F (15.5 °C).
What it does not mean
Lo is not a low-battery warning: every thermometer read here has a separate battery symbol. It is not stored as a temperature either: Omron says its ET720 memory keeps the last results “excluding Hi/Lo results”.
Other symbols with the same shapes
Sources
No published standard we could check defines the symbols on a digital thermometer’s display, so this meaning is taken from 8 makers’ own manuals and support pages, each fetched and read on the date shown:
- Omron: Omron No-Touch Forehead Thermometer ET720 (MC-720-Z) — instruction manual (US, 5681249-5D, PDF) — Taking a Reading: “If the result is lower than 93.2°F (34.0°C), Lo appears on the display”; error table: surface measurement mode lower than -7.6°F (-22°C), “Use the unit within its measurable range”; memory stores the last 25 results “excluding Hi/Lo results”. Checked 2026-09-29.
- Braun: Braun ThermoScan 7 (IRT 6520) and ThermoScan 3 (IRT 6030) infrared ear thermometers — instruction manual (Asia-Pacific, PDF) — Errors and troubleshooting: “Temperature taken is not within typical human temperature range (34 – 42.2 °C or 93.2 – 108 °F). HI = too high, LO = too low”, with the fix quoted on this page. Checked 2026-09-29.
- Microlife: Microlife NC 200 non-contact thermometer — instruction manual (IB NC 200-e N-V10, 2026-08-17, PDF) — Error messages: «L» = too low, measured temperature lower than 34 °C / 93.2 °F in body mode or 0.1 °C / 32.2 °F in object mode; “Make sure the measuring sensor is clean. Then, take a measurement again.” Checked 2026-09-29.
- Microlife: Microlife MT 410 digital stick thermometer — instruction manual (IB MT 410, revision 2025-07-03, PDF) — Turning on the thermometer: at an ambient temperature below 32°C an «L» and a flashing «°C» appear and “The thermometer is now ready for use”; technical specifications: Temp. < 32.0°C: display «L». Checked 2026-09-29.
- Microlife: Microlife Ear Thermometer IR 310 — instruction manual (IB IR 310 N-V10, revision 2024-09-13, PDF) — Error Messages: Measured temperature too low, «L» when the measured temperature is lower than 32 °C / 89.6 °F. Checked 2026-09-29.
- Beurer: Beurer FT 95 non-contact thermometer — instructions for use (2021-06-22, PDF) — Error messages: forehead temperature mode, determined temperature lower than 34 °C (93.2 °F); object temperature mode lower than 0 °C; “Operate the thermometer only within the specified temperature ranges.” Checked 2026-09-29.
- Withings: Withings Thermo — regulatory information and troubleshooting (PDF) — Troubleshooting: “Error” — “The temperature is outside ranges. i.e lower than 35°C (95°F) or higher than 43.2°C (109.76°F)”; make a new measurement. Checked 2026-09-29.
- iProven: iProven Digital Thermometer DT-K 117A / B — instruction manual (US, manual version 20151223, PDF) — Operating Instructions: “When the letters “Lo” and a flashing “ºC” or “ºF” displays for 5 seconds, the thermometer is ready for use”; Explanation of symbols: “Lo ºC or Lo ºF — Temperature is under 32 ºC or 89.6 ºF”. Checked 2026-10-09.
- Vicks: Vicks SpeedRead Digital Thermometer V912CA (model V912CAV1) — owner’s manual (Canada, English and French, PDF) — Turning the unit on: “After about 5 seconds, the display will show it’s ready (Fig. 4)”; changing the scale: “press and hold the power button for about 5 seconds until “Lo” (Fig. 4) appears in the screen”; Specifications, Temperature Range: “If more than 43°C (109.4°F), “Hi” is displayed”. Checked 2026-10-09.
- Exergen: Exergen TemporalScanner TAT-2000C Dual Mode — instructions for use (818805 rev 4, PDF) — Display Messages: “Temperature measured is lower than 60 °F (15.5 °C)”, beside a picture of the screen; specifications: Temperature Range 16 to 42°C (61 to 107.6°F). Checked 2026-10-09.
Written in our own words; quotations are the makers’ wording.