FireAngel alarm signals: beeps, chirps and lights
FireAngel’s FA6611, FA6615 and FA6620 smoke alarms (and the FA6720 heat alarm) count their warnings on a 40-second beat: one beep, a double beep or a triple beep, each with the same number of red flashes. Its CO alarms use four loud beeps for an alarm and a slower red flash for alarm memory.
What people ask
Why is my FireAngel smoke alarm beeping? FireAngel: when its self-check finds a fault “or if the batteries are low, the detector will emit a single chirp once per minute for 30 days.” “If the red LED flashes at a separate time from the chirp, a fault is indicated.” On this page: One beep and one flash every 40 seconds · A double beep and a double flash every 40 seconds.
Source: FireAngel Safety Technology, Why is my FireAngel smoke alarm beeping? Checked 2026-10-13.
5 more: stopping the beep, keeps going off, flashing red, CO alarm beeping, CO alarm flashing red
How do I stop my FireAngel smoke alarm from beeping? For a false alarm FireAngel says “press the large central test button to silence”, and its manual’s Sleep Easy feature covers the night: “If a low battery ‘chirp’ occurs at night, the alarm can be silenced so it does not keep you from sleeping.” That only buys time: “A low battery warning chirp can only be silenced a maximum of 10 times”, and “If a sealed-battery alarm is emitting a low-battery chirp and is no longer under warranty, the whole unit will need to be replaced.” On this page: One beep and one flash every 40 seconds · Quiet after pressing Test, LED still flashing once a second.
Sources: FireAngel Safety Technology, Why is my FireAngel smoke alarm beeping? Checked 2026-10-13. · FireAngel Safety Technology, FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual Checked 2026-10-13.
Why does my FireAngel alarm keep going off? FireAngel: “A common cause of nuisance alarms is the incorrect positioning of a smoke or heat alarm”, for example “too close to doors or windows”, or in “bathrooms, shower rooms or any other very damp and humid areas, where moisture can cause unwanted alarms.” Dust is the other: it says to clean alarms “every 3 months” with a vacuum’s soft brush or a hairdryer on a cool setting, and to replace one with “any visible damage”, “including any severe staining or dust”. If you are not certain there is no fire, follow FireAngel’s emergency instruction below first. On this page: Loud alarm, red LED flashing once a second · Quiet after pressing Test, LED still flashing once a second.
Source: FireAngel Safety Technology, Why is my FireAngel smoke alarm beeping? Checked 2026-10-13.
Why is my FireAngel smoke alarm flashing red? A slow red flash is normal: FireAngel’s FAQ says an alarm fitted correctly to its baseplate “should show a green LED, with a red LED flash every 30-45 seconds”, and if it does not, its first fix is “detaching the alarm from the baseplate and reattaching to stop the beeping.” A red flash that comes at a different moment from a chirp is not: “If the red LED flashes at a separate time from the chirp, a fault is indicated.” On this page: One red flash about every 40 seconds, no sound · A double beep and a double flash every 40 seconds.
Sources: FireAngel Safety Technology, Fire & Smoke Alarm FAQs Checked 2026-10-13. · FireAngel Safety Technology, Why is my FireAngel smoke alarm beeping? Checked 2026-10-13.
Why is my FireAngel carbon monoxide alarm beeping? Four loud beeps is the alarm: FireAngel says “immediately open any doors or windows in your home, stop using any appliances, switch them off and evacuate the building taking the CO alarm with you”, and if it stops after 10 minutes in fresh air, call your gas supplier or the “national emergency gas helpline on 0800 111 999”. Quieter regular beeps are different, but not harmless: “If your CO alarm is beeping once, twice or three times regularly, you may need to replace your alarm batteries, or you could be experiencing exposure to low levels of CO.” The guide covers the FA3313 and FA3820. On this page: Four loud beeps and a pause, repeating (CO alarm).
Source: FireAngel Safety Technology, Why is my FireAngel CO alarm beeping and flashing? Checked 2026-10-13.
Why is my FireAngel carbon monoxide alarm flashing red? FireAngel’s guide for the FA3313 and FA3820: “If your CO alarm is flashing a red LED light every 20 seconds, it has been activated recently. This is referred to as ‘alarm memory’.” If it sounds again with four loud beeps, the same guide says to open windows, switch off appliances and get out with the alarm. On this page: CO alarm flashing red every 20 seconds, silent.
Source: FireAngel Safety Technology, Why is my FireAngel CO alarm beeping and flashing? Checked 2026-10-13.
The questions are what people search (Google Search Console and Google’s search suggestions); each answer comes only from the FireAngel documents named under it.
If it is sounding a full alarm: the maker’s emergency instruction
Smoke alarm
FireAngel: never ignore any alarm. If your smoke or heat alarm goes off and you are not absolutely certain of the source, get everyone out of the house immediately — sleeping children first — and call the fire and rescue service without delay, however small the fire (FireAngel’s FAQ: evacuate immediately and call 999).
From FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual and Fire & Smoke Alarm FAQs.
Carbon monoxide alarm
FireAngel: if the CO alarm goes off with four loud beeps, immediately open doors and windows, stop using any appliances and switch them off, and leave the building taking the CO alarm with you. If it stops after 10 minutes in fresh air, you may have a CO leak: call your gas supplier or the national gas emergency line on 0800 111 999 and wait for instructions. Do not go back in until it has been declared safe.
From Why is my FireAngel CO alarm beeping and flashing? and Fire & Smoke Alarm FAQs.
Every FireAngel signal we could source, side by side
9 signals. Tap what it means to jump to the drawing, FireAngel’s steps and the source. If your alarm’s pattern is not exactly one of these, check the manual for your model: FireAngel models do not all use the same signals.
| What you see | What you hear | What it means |
|---|---|---|
| One red flash about every 40 seconds | Silent | Normal operation: Normal operation: after activation the red LED flashes about once every 40 seconds to show the alarm is active. |
| One red flash about every second | Full alarm, loud and continuous | Real alarm: Smoke (or, on the FA6720, heat) has been detected. |
| One red flash about every second | Silent | Hush or silence mode: Silence mode after a known false alarm: the alarm is quiet for 10 minutes, the LED keeps flashing once a second, and it returns to full sensitivity by itself. |
| One red flash about every 40 seconds | One chirp about every 40 seconds | Low battery: Low battery. |
| Two red flashes about every 40 seconds | Two chirps about every 40 seconds | Fault: Fault: FireAngel says the alarm may not signal an alert. |
| Three red flashes about every 40 seconds | Three chirps about every 40 seconds | End of life: End of life: FireAngel says the alarm may not signal an alert. |
| Red light | Full alarm, four beeps then a pause, repeating | Real alarm: Carbon monoxide has been detected. |
| One red flash about every 20 seconds | Silent | Alarm memory: Alarm memory: the CO alarm has been activated recently, possibly while nobody was home (FA3313 and FA3820). |
| Three yellow or amber flashes about every 60 seconds | Three chirps about every 60 seconds | End of life: End of life on the FA6829S CO alarm: its 10-year sensor and battery are used up. |
One red flash about every 40 seconds, no sound
Normal operation · smoke
Normal operation: after activation the red LED flashes about once every 40 seconds to show the alarm is active.
- What you see
- One red flash about every 40 seconds
- What you hear
- Silent
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- Nothing to do. FireAngel says to test monthly and vacuum the alarm every 3 months. If the flash stops altogether, its FAQ says the battery may be spent (FA6615) or at end of life (FA6620).
Source:
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
Loud alarm, red LED flashing once a second
Real alarm · smoke
Smoke (or, on the FA6720, heat) has been detected. FireAngel’s FAQ: if the red light flashes more often than normal or the alarm sounds, smoke has been detected.
- What you see
- One red flash about every second
- What you hear
- Full alarm, loud and continuous
Do this first: FireAngel’s smoke alarm instruction, top of this page
What FireAngel says to do about this signal
- Get out first (above). Only for a known false alarm — burnt toast you can see — press the Test button to silence it for 10 minutes.
Source:
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
Quiet after pressing Test, LED still flashing once a second
Hush or silence mode · smoke
Silence mode after a known false alarm: the alarm is quiet for 10 minutes, the LED keeps flashing once a second, and it returns to full sensitivity by itself.
- What you see
- One red flash about every second
- What you hear
- Silent
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- If the alarm will not test while it is in low-sensitivity mode, FireAngel says to wait 15 minutes and try again.
Source:
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
On its own page: Quiet after pressing Test, LED still flashing once a second
One beep and one flash every 40 seconds
Low battery · smoke
Low battery.
- What you see
- One red flash about every 40 seconds
- What you hear
- One chirp about every 40 seconds
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- FA6611 and FA6615 (2 × AA): replace the batteries, then test the alarm.
- FA6620 and FA6720 (sealed battery): replace the whole alarm within 30 days; if it is under warranty, contact FireAngel Technical Support.
- Sleep Easy: pressing Test silences the low-battery beep for 8 hours; FireAngel says to act the next day.
Source:
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
On its own page: One beep and one flash every 40 seconds
A double beep and a double flash every 40 seconds
Fault · smoke
Fault: FireAngel says the alarm may not signal an alert.
- What you see
- Two red flashes about every 40 seconds
- What you hear
- Two chirps about every 40 seconds
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- Replace the alarm immediately. If it is still under warranty, contact FireAngel Technical Support.
Source:
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
On its own page: A double beep and a double flash every 40 seconds
A triple beep and a triple flash every 40 seconds
End of life · smoke
End of life: FireAngel says the alarm may not signal an alert.
- What you see
- Three red flashes about every 40 seconds
- What you hear
- Three chirps about every 40 seconds
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- Replace the alarm immediately. FireAngel says to replace the alarm every 10 years in any case; its support page says the replace-by date is printed on the base.
Source:
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Why is my FireAngel smoke alarm beeping? — FireAngel smoke and heat alarms (support article). www.fireangel.co.uk Checked 2026-09-29.
On its own page: A triple beep and a triple flash every 40 seconds
Four loud beeps and a pause, repeating (CO alarm)
Real alarm · carbon monoxide
Carbon monoxide has been detected. On the FA6829S the display also shows ALARM and the CO level in ppm.
- What you see
- Red light
- What you hear
- Full alarm, four beeps then a pause, repeating
Do this first: FireAngel’s carbon monoxide alarm instruction, top of this page
What FireAngel says to do about this signal
- Follow FireAngel’s CO instruction (above).
- If the alarm did not stop after 10 minutes in fresh air, FireAngel says to contact its Customer Support if it is under warranty, or replace it.
Source:
- FireAngel Safety Technology: Why is my FireAngel CO alarm beeping and flashing? — FA3313 and FA3820 CO alarms (support article). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
On its own page: Four loud beeps and a pause, repeating (CO alarm)
CO alarm flashing red every 20 seconds, silent
Alarm memory · carbon monoxide
Alarm memory: the CO alarm has been activated recently, possibly while nobody was home (FA3313 and FA3820).
- What you see
- One red flash about every 20 seconds
- What you hear
- Silent
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- FireAngel’s support page names the signal without a separate step. Its FA3820 FAQ says the 30-day memory is there so you can check whether CO was detected while you were away — and if it was, FireAngel’s CO instruction (above) is what it says to do about CO.
Source:
- FireAngel Safety Technology: Why is my FireAngel CO alarm beeping and flashing? — FA3313 and FA3820 CO alarms (support article). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
On its own page: CO alarm flashing red every 20 seconds, silent
Three rapid beeps and three yellow flashes every 60 seconds (FA6829S)
End of life · carbon monoxide
End of life on the FA6829S CO alarm: its 10-year sensor and battery are used up.
- What you see
- Three yellow or amber flashes about every 60 seconds
- What you hear
- Three chirps about every 60 seconds
If it is sounding a full alarm instead: FireAngel’s emergency instruction, top of this page
What FireAngel says to do about this signal
- Replace the whole unit immediately. FireAngel says the electrochemical sensor wears out over time and cannot be serviced or recalibrated.
Source:
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
On its own page: Three rapid beeps and three yellow flashes every 60 seconds (FA6829S)
Sources
Every line on this page comes from FireAngel’s own documents, read on the date shown. Nothing is taken from third-party code sites or other makes.
- FireAngel Safety Technology: FA6611, FA6615 & FA6620 Optical Smoke Alarm & FA6720 Heat Alarm — User Manual — FA6611, FA6615, FA6620, FA6720 (document GN5914R3). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Why is my FireAngel CO alarm beeping and flashing? — FA3313 and FA3820 CO alarms (support article). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Fire & Smoke Alarm FAQs — FA6615-R, FA6620-R, FA6829S, FA3820-EUX10 (FAQ entries). www.fireangel.co.uk Checked 2026-09-29.
- FireAngel Safety Technology: Why is my FireAngel smoke alarm beeping? — FireAngel smoke and heat alarms (support article). www.fireangel.co.uk Checked 2026-09-29.